[Hawach Scientific] Empty Flash Columns
Ordering Information
SLEP0004PF | 4g empty solid load cartridge with screw cap, frits, tips and O-ring | optional |
SLEP0012PF | 12g empty solid load cartridge with screw cap, frits, tips and O-ring | optional |
SLEP0025PF | 25g empty solid load cartridge with screw cap, frits, tips and O-ring | optional |
SLEP0040PF | 40g empty solid load cartridge with screw cap, frits, disbursing unit, tips and O-ring | optional |
SLEP0080PF | 80g empty solid load cartridge with screw cap, frits, disbursing unit, tips and O-ring | optional |
SLEP0120PF | 120g empty solid load cartridge with screw cap, frits, disbursing unit, tips and O-ring | optional |
SLEP0220PF | 220g empty solid load cartridge with screw cap, frits, disbursing unit, tips and O-ring | optional |
SLEP0330PF | 330g empty solid load cartridge with screw cap, frits, disbursing unit, tips and O-ring | optional |
Weight: 4g, 12g , 25g, 40g, 60g, 80g, 100g, 120g, 220g, 330g
Surface pH: 6.3-7.2
Length: 115.1, 137.8, 188.2, 188.7, 173.3, 263.5, 146.6, 277.7, 218.5, 271.6
Description of Empty Flash Columns
Empty chromatography columns body of the fast separation column is made of medical-grade polypropylene (PP) material, which avoids the dissolution pollution of ordinary PP materials to the separated samples. In addition, the transparent PP material cylinder allows users to visually observe the separation of samples. The Empty columns design enables the fast separation column to withstand pressure up to 300 psi and is safe and leak-free. The empty chromatography column has a Luer-Lock standard connector and can be used on various fast liquid chromatography separation systems.
Empty Flash Columns from Hawach Scientific allows the end-user to add their own sorbet according to a different application. Our Empty Flash Columns(Empty solid load cartridge with the screw cap, frits, tips, and O-ring, and end tips and disbursing unit for columns larger than 40g ), we provide users convenience for themselves manual assembly for a flexible sample loading method: solid load or their direct liquid injection. The standard Luer-lock end fittings are the idea for quick and easy connection to most of the flash systems such as Biotage, and Yamazen.
Advantage of Empty Chromatography Column
Empty flash column for the customized column by users packing material
Meet a variety of needs for specific purifications
The wide range of specifications for different purifications needs satisfying
Standard Luer connection for the easier match to the flash system
Features
Surface pH: 6.3-7.2
Customized Color for top screw cap for flash column
Cartridge with the maximum operating pressure up to 200 psi
Clean column and clean packing and excellent column pressure
Medical PP cartridge tube makes no extractable and wide compatibility
The frits for the column from 4g to 40g with the pore size of 16~20um
Only for the bigger column of 80g~330g, the pore size is bigger as 20~25um
Innovative flash column design is convenient for manual assembly and stacking
Column Length: 115.1, 137.8, 188.2, 188.7, 173.3, 263.5, 146.6, 277.7, 218.5, 271.6
Size available in 4g, 12, 25g, 40g, 80g, 120g, 220g, 330g, etc can meet most customers’ needs
Disbursing unit available for columns larger than 40g to ensure better flow rate and leakage-free
Applications
Be used as a solid load cartridge for flash chromatography
Technical Data
'Hawach Scientific' 카테고리의 다른 글
[Hawach Scientific] QuEChERS Dispersive Absorbents (1) | 2022.09.26 |
---|---|
[Hawach Scientific] Quantitative Filter Paper Grade: BIO-40 (0) | 2022.09.13 |
[Hawach Scientific] C18-Aqueous HPLC Columns (0) | 2022.08.05 |
[Hawach Scientific] Cellulose Acetate Syringe Filters (0) | 2021.06.10 |
[Hawach Scientific] Sterile MCE Syringe Filters (0) | 2020.08.25 |