[Hawach Scientific] Cellulose Acetate Syringe Filters
Filter Media | Cellulose Acetate | ||||
Diameter | 4mm | 13mm | 25mm | 33mm | 50mm |
Housing | Medical PP | ||||
Pore Size | 0.1μm, 0.22μm, 0.45μm, 0.8μm, 1.0μm, 3.0μm, 5.0μm | ||||
Filtration Area | 0.2cm2 | 1.3cm2 | 4.9cm2 | 8.5cm2 | 19.8cm2 |
Maximum Pressure | 5.2bar | ||||
Process Volume | 2mL | 10mL | 100mL | 200mL | 5000mL |
Pre-filter | 1μm GF or PP | ||||
Hold-up Volume | < 10μL | < 50μL | < 100μL | < 200μL | < 350μL |
Inlet | Female Luer Lock | Stepped barb | |||
Outlet | Male Luer slip | Stepped barb | |||
Operate temperature | 60°C |
Instruction Drawing
Ordering Information
Item Code | Diameter(mm) | Pore Size(μm) | Pre-filter | Quantity/pk |
SLCA0410N | 4 | 0.1 | No | 100pcs |
SLCA0422N | 0.22 | |||
SLCA0445N | 0.45 | |||
SLCA0480N | 0.8 | |||
SLCA04100N | 1 | |||
SLCA04300N | 3 | |||
SLCA04500N | 5 | |||
SLCA1310N | 13 | 0.1 | No | 100pcs |
SLCA1322N | 0.22 | |||
SLCA1345N | 0.45 | |||
SLCA1380N | 0.8 | |||
SLCA13100N | 1 | |||
SLCA13300N | 3 | |||
SLCA13500N | 5 | |||
SLCA1310NP | 0.1 | PP | ||
SLCA1322NP | 0.22 | |||
SLCA1345NP | 0.45 | |||
SLCA1380NP | 0.8 | |||
SLCA13100NP | 1 | |||
SLCA13300NP | 3 | |||
SLCA13500NP | 5 | |||
SLCA1310NG | 0.1 | GF | ||
SLCA1322NG | 0.22 | |||
SLCA1345NG | 0.45 | |||
SLCA1380NG | 0.8 | |||
SLCA13100NG | 1 | |||
SLCA13300NG | 3 | |||
SLCA13500NG | 5 | |||
SLCA2510N | 25 | 0.1 | No | 100pcs |
SLCA2522N | 0.22 | |||
SLCA2545N | 0.45 | |||
SLCA2580N | 0.8 | |||
SLCA25100N | 1 | |||
SLCA25300N | 3 | |||
SLCA25500N | 5 | |||
SLCA2510NP | 0.1 | PP | ||
SLCA2522NP | 0.22 | |||
SLCA2545NP | 0.45 | |||
SLCA2580NP | 0.8 | |||
SLCA25100NP | 1 | |||
SLCA25300NP | 3 | |||
SLCA25500NP | 5 | |||
SLCA2510NG | 0.1 | GF | ||
SLCA2522NG | 0.22 | |||
SLCA2545NG | 0.45 | |||
SLCA2580NG | 0.8 | |||
SLCA25100NG | 1 | |||
SLCA25300NG | 3 | |||
SLCA25500NG | 5 | |||
SLCA3310N | 33 | 0.1 | No | 50pcs |
SLCA3322N | 0.22 | |||
SLCA3345N | 0.45 | |||
SLCA3380N | 0.8 | |||
SLCA33100N | 1 | |||
SLCA33300N | 3 | |||
SLCA33500N | 5 | |||
SLCA3310NP | 0.1 | PP | ||
SLCA3322NP | 0.22 | |||
SLCA3345NP | 0.45 | |||
SLCA3380NP | 0.8 | |||
SLCA33100NP | 1 | |||
SLCA33300NP | 3 | |||
SLCA33500NP | 5 | |||
SLCA3310NG | 0.1 | GF | ||
SLCA3322NG | 0.22 | |||
SLCA3345NG | 0.45 | |||
SLCA3380NG | 0.8 | |||
SLCA33100NG | 1 | |||
SLCA33300NG | 3 | |||
SLCA33500NG | 5 | |||
SLCA5010N | 50 | 0.1 | No | 25pcs |
SLCA5022N | 0.22 | |||
SLCA5045N | 0.45 | |||
SLCA5080N | 0.8 | |||
SLCA50100N | 1 | |||
SLCA50300N | 3 | |||
SLCA50500N | 5 | |||
SLCA5010NP | 0.1 | PP | ||
SLCA5022NP | 0.22 | |||
SLCA5045NP | 0.45 | |||
SLCA5080NP | 0.8 | |||
SLCA50100NP | 1 | |||
SLCA50300NP | 3 | |||
SLCA50500NP | 5 | |||
SLCA5010NG | 0.1 | GF | ||
SLCA5022NG | 0.22 | |||
SLCA5045NG | 0.45 | |||
SLCA5080NG | 0.8 | |||
SLCA50100NG | 1 | |||
SLCA50300NG | 3 | |||
SLCA50500NG | 5 |
Description of Cellulose Acetate Syringe Filters
Cellulose Acetate Syringe Filters combine high flow rates and thermal stability with very low absorption characteristics, suitable for filtration of proteins and enzymes, sterilization of tissues, and culture media.
In HPLC analysis, the particle size of the chromatographic column packing is small and it is easy to be blocked by impurity particles. Therefore, samples and solvents need to be filtered in advance to remove particulate contaminants and protect the instrument.
Ion chromatography, which is commonly used in environmental analysis, also requires that no inorganic contaminants be introduced in sample pretreatment. Syringe filters can be used in HPLC analysis and IC analysis. Filtering sample solutions is an important step in the sample pretreatment process.
Advantage of Cellulose Acetate Syringe Filters
Hydrophilic CA syringe filters
Low protein binding
High throughput
Excellent strength and stability
Option standard 1um pre-filter providing increased sample handling capacity
Applications of Cellulose Acetate Syringe Filters
HPLC sample preparation
Biological sample preparation
Protein and enzyme filtration
Cell culture
Clarification of aqueous and alcohol solutions
Filtration of aqueous-based solutions or biologic samples
Chemical Compatibility
Incompatible with Organic solvents: Acids, NaOH, dichloromethane, chloroform, ketones, DMSO, THF
'Hawach Scientific' 카테고리의 다른 글
[Hawach Scientific] Quantitative Filter Paper Grade: BIO-40 (0) | 2022.09.13 |
---|---|
[Hawach Scientific] Empty Flash Columns (0) | 2022.08.17 |
[Hawach Scientific] C18-Aqueous HPLC Columns (0) | 2022.08.05 |
[Hawach Scientific] Sterile MCE Syringe Filters (0) | 2020.08.25 |
[Hawach Scientific] NH2 HPLC Columns (0) | 2020.08.19 |