본문 바로가기
Hawach Scientific

[Hawach Scientific] C8 Low pH HPLC Column

by 휴바이오랩(Hubiolab) 2024. 1. 18.

[Hawach Scientific]  C8 Low pH HPLC Column

SLHC8L32130 C8-Low pH, 3μm, 120Å, 2.1x30mm 1
SLHC8L32133 C8-Low pH, 3μm, 120Å, 2.1x33mm 1
SLHC8L32150 C8-Low pH, 3μm, 120Å, 2.1x50mm 1
SLHC8L32175 C8-Low pH, 3μm, 120Å, 2.1x75mm 1
SLHC8L321100 C8-Low pH, 3μm, 120Å, 2.1x100mm 1
SLHC8L321125 C8-Low pH, 3μm, 120Å, 2.1x125mm 1
SLHC8L321150 C8-Low pH, 3μm, 120Å, 2.1x150mm 1
SLHC8L321200 C8-Low pH, 3μm, 120Å, 2.1x200mm 1
SLHC8L321250 C8-Low pH, 3μm, 120Å, 2.1x250mm 1
SLHC8L33030 C8-Low pH, 3μm, 120Å, 3.0x30mm 1
SLHC8L33050 C8-Low pH, 3μm, 120Å, 3.0x50mm 1
SLHC8L33075 C8-Low pH, 3μm, 120Å, 3.0x75mm 1
SLHC8L330100 C8-Low pH, 3μm, 120Å, 3.0x100mm 1
SLHC8L330125 C8-Low pH, 3μm, 120Å, 3.0x125mm 1
SLHC8L330150 C8-Low pH, 3μm, 120Å, 3.0x150mm 1
SLHC8L330200 C8-Low pH, 3μm, 120Å, 3.0x200mm 1

Column: XChroma HPLC Column, C8-Low PH, 5μm, 4.6×250mm
Mobile Phase: A: 1.0mL TcMB, duplicate in 1000mL water B:acetonitrile
Wavelength: 285nm
Temperature: 40°C
Flow Rate: 1mL / min
Injection Volume: 20μL
Notes: After every injection, need 10 column volume to get gradient equilibrium

 

Hawach C8-Low pH HPLC Column in the acidic conditions of the mobile phase has a good separation performance, stability, and longer service life. It is suitable for the separation of polarizable objects at extremely low pH to medium pH, the pH range is 0.5-8.0.

The main reason for high performance liquid chromatography in phytochemical analysis for the shortened lifetime in low pH mobile phases is that the bonded phase is hydrolyzed under acidic conditions, which will cause significant changes in retention time and peak shape; at the same time, the hydrolysis of the bonded phase will cause LC-MS The increased detection background of the analysis affects the sensitivity and durability of the method.

C8 low ph HPLC columns science equipment suppliers adopt advanced bonding and end group sealing technology to produce. Compared with columns obtained by traditional bonding technology, C8 low pH HPLC columns have better stability and reproducibility and can inhibit the hydrolysis of the bonded phase under low pH conditions.

Features of C8 Low pH HPLC Column

  • C8-Low pH Ultra-pure all-porous silica gel, pure >99.999%;
  • Resistant 100% aqueous phase;
  • The C8 low PH HPLC column has better retention capability for substances with higher polarity than C18 low PH HPLC column but does not retain as well as C18 for substances with small polarity;
  • Compared with C18-Low pH a slightly smaller selective provision of 300Å aperture to meet large molecular biological separation needs;
  • Unique fixed phase bonding;
  • pH Range: 1.0-8.0;
  • Particle size: 120Å, 300Å for choice.