[HepatoChem] Lucent 360™ Advanced Photoreactor

The Lucent360™ Advanced Photoreactor enables parallel (screen), batch and flow with wavelength, light intensity and temperature control in one device.
- Multiple vial formats and configurations (from 0.3 ml to 700 ml)
- Temperature controlled (0°C to 80°C) with thermostatic fluid
- Interchangeable LED light modules (254 nm through 808 nm)
- Screen up to 4 wavelengths and/or light intensities simultaneously
- Heavy duty magnetic stirring
- Pre-set your favorite experiments for quick repeatability
Industry Leading Photoreactor Design
The Lucent360™ Advanced Photoreactor is the most comprehensive photoreactor on the market. It’s patented design provides the most flexibility for parallel, large batch and flow photochemistry. Reaction vials are immerged in a thermostatic bath controlled by an external heater/ chiller unit, enabling temperature controlled experiment conditions. Light irradiation is provided by custom, interchangeable light modules that surround the reaction chamber. The reaction chamber itself is comprised of 2 glass walls (Dewar) that thermally insulate light sources from the reaction vial bath.
Designed for maximum control of samples irradiation


Unparalleled Control of Light Wavelengths and Intensities
The Lucent360™ includes 5 light modules that can be controlled independently. Each module has multiple LEDs that operate at a specific wavelength.
The light modules are interchangeable and, when using a light screening holder in the reaction chamber, enables conditions that can screen multiple wavelengths or light intensities simultaneously.


Light Irradiance Screening
Each light module is set at different intensity to investigate quantum yield of your reactions.

Module 1: 100% Module 2: 75%
Module 3: 50% Module 4: 25%

Wavelength Screening
Each light can be set with a different wavelengths to study several catalytic systems simultaneously.

Module 1: 365 nm Module 2: 450 nm
Module 3: 450 nm Module 4: 525 nm

Timecourse Experiment
Each light module can be set with different irradiation time in parallel or in sequence.

Module 1: 30 min Module 2: 60 min
Module 3: 120 min Module 4: 240 nm

Interchangeable Light Modules
Side Light Module

Bottom Light Module

Easy Access to Light Modules

Wavelengths Available:
254 nm, 275 nm, 300 nm, 310 nm, 340 nm, 365 nm, 380 nm, 390 nm, 405 nm, 425 nm, 427 nm, 440 nm, 450 nm, 475 nm, 505 nm, 525 nm, 595 nm, 650 nm, 740 nm and 808 nm.

'HepatoChem' 카테고리의 다른 글
| [HepatoChem] EvoluChem LED 254PF Dimmable 110V (0) | 2026.08.03 |
|---|---|
| [HepatoChem] PhotoRedOx Box™ (0) | 2026.07.29 |
| [HepatoChem] PhotoRedOx Box TC™ (0) | 2026.07.03 |
| [HepatoChem] Plate Light 365 nm (0) | 2026.06.18 |
| [HepatoChem] PhotoRedOx Box™ (0) | 2026.06.16 |